Epimedium Extract (Icariin 98%)

Ureda Naturals manufactures Epimedium Extract standardized to ≥98.0% Icariin by HPLC. Produced from Epimedium brevicornu Maxim. leaves, this high-purity grade is intended for capsules, tablets, suspension systems and engineered delivery formulations.

Additional information

Product Name

Epimedium Extract (Icariin 98%)

Botanical Source

Epimedium brevicornu Maxim.

Active Compound

Icariin

CAS No.

489-32-7

Assay

≥98.0% by HPLC

Ureda Naturals manufactures Epimedium Extract standardized to not less than 98.0% Icariin by HPLC. The extract is produced from Epimedium brevicornu Maxim. leaves using water and ethanol extraction followed by purification.

The high Icariin concentration reduces the amount of broader botanical matrix entering a formula but increases sensitivity to low-dose distribution, powder consolidation and process loss. Limited aqueous solubility also makes dosage-form selection and finished-product performance testing critical.

Product Profile

Product name Epimedium Extract (Icariin 98%)
Active compound Icariin
CAS number 489-32-7
Molecular formula C33H40O15
Molecular weight 676.66 g/mol
Botanical source Epimedium brevicornu Maxim.
Plant part Leaf
Extraction solvents Water and ethanol
Assay ≥98.0% Icariin by HPLC
Appearance Brown-yellow powder
Particle size 100% through 80 mesh
Identification Positive by TLC
Packaging 25 kg cardboard drum with double-layer inner bags
Shelf life 24 months
Storage Cool, dry and protected from strong light and heat

Grade Identity

Material Defining specification Technical distinction
Epimedium Extract (Icariin 98%) Purified Epimedium leaf extract standardized to ≥98.0% Icariin Provides a defined, high-purity Icariin input
Standardized Epimedium extract Botanical extract adjusted to a lower declared Icariin level Introduces more accompanying botanical constituents
Total Epimedium flavonoids Combined flavonoid-group assay The reported percentage does not equal Icariin content
Icariside II Deglycosylated Icariin-related compound Different identity and analytical response
Icaritin Icariin aglycone Different physicochemical behavior

Replacing a lower-assay standardized Epimedium extract with the 98% Icariin grade changes the constituent profile, ingredient mass and active-to-carrier ratio. Existing blend, recovery and stability data must therefore be revalidated.

Application Fit

Finished-product format Technical assessment Critical control
Dry-filled capsules Suitable after blend qualification Segregation, feeding and dosage-unit uniformity
Tablets Suitable after process qualification Granulation recovery, compression and dissolution
Reconstituted sachets Suitable for suspension-format products Wetting, sedimentation and delivered dose
Suspension liquids Feasible with an engineered vehicle Rheology, settling and filling uniformity
Clear aqueous liquids Requires a separate delivery system Dissolved fraction and precipitation control
Gummies Requires matrix-specific validation Heat recovery, cooling behavior and unit uniformity

Critical Manufacturing Controls

Low-Inclusion Blending

The high assay reduces the quantity of extract added to the production batch. A qualified premix is required when direct addition cannot produce acceptable Icariin uniformity.

  • Define the carrier and active-to-carrier premix ratio.
  • Control the addition sequence and blender fill level.
  • Establish the mixing endpoint from multi-location assay results.
  • Compare uniformity before discharge and after transfer.
  • Test units from the beginning, middle and end of filling.

Increased assay variation after additional mixing or handling indicates re-segregation.

Density and Consolidation

  • Bulk density: 0.4521 g/mL
  • Tapped density: 0.5932 g/mL
  • Hausner ratio: approximately 1.31
  • Carr index: approximately 23.8%

The measured consolidation can affect hopper discharge, volumetric feeding, capsule filling and separation from formulation components with different density. Production trials should reproduce expected vibration, hopper residence and transfer conditions.

Particle-Size Control

The 80-mesh specification excludes coarse particles but does not define D10, D50, D90, fine-particle fraction, agglomeration or specific surface area.

Where particle behavior affects premixing, feeding, wetting, dissolution or suspension stability, purchasing limits should be established from full particle-size and application-performance data.

Process Recovery

Sampling stage Primary failure identified
Dispensed material Weighing or starting-potency error
Initial premix Incomplete distribution or container retention
Multiple final-blender locations Blend non-uniformity
Discharged blend Transfer-induced segregation
Material at filling equipment Hopper or feeding instability
Beginning, middle and end of filling Progressive segregation or settlement
Before and after filtration Insoluble-particle or filter retention
Finished-product extraction Matrix-related analytical recovery

Dosage-Form Development

Capsules

Evaluate premix uniformity, segregation after transfer, hopper consolidation, fill-weight variation, dosage-unit Icariin content and dissolution. Capsule weight and Icariin content must be evaluated separately.

Tablets

Evaluate recovery after granulation and drying, active migration during drying, uniformity after lubrication, assay after compression and finished-tablet dissolution. Hardness, friability and disintegration do not establish Icariin release.

Suspensions and Reconstituted Powders

Measure wetting, agglomeration, sedimentation, sediment compactness, redispersibility, concentration during filling or consumption and the dose remaining in the preparation container.

Clear Aqueous Systems

Establish equilibrium solubility, dissolved Icariin after validated phase separation, filtration recovery, dilution stability, temperature-cycle stability, pH and electrolyte effects, storage precipitation and filling-stage concentration.

Gummies

Control the addition stage, maximum temperature, exposure time, post-heating recovery, distribution before depositing, cooling precipitation, individual-piece content and storage stability.

Specification and COA

Test Specification COA result Method
Appearance Brown-yellow powder Conforms Visual
Icariin ≥98.0% 98.21% HPLC
Particle size 100% through 80 mesh Conforms ChP 2020
Identification Positive Positive TLC
Moisture ≤5.0% 3.59% ChP 2020
Total ash ≤5.0% 1.87% ChP 2020
Bulk density Report value 45.21 g/100 mL ICH Q4B Annex 13
Tapped density Report value 59.32 g/100 mL ICH Q4B Annex 13
Total heavy metals ≤10 ppm Conforms ChP 2020
Lead ≤2.0 mg/kg Conforms GB 5009.12
Arsenic ≤1.0 mg/kg Conforms GB 5009.11
Mercury ≤0.3 mg/kg Conforms GB 5009.17
HCH ≤0.2 mg/kg Conforms GB 5009.19
DDT ≤0.2 mg/kg Conforms GB 5009.19
Total plate count ≤1,000 CFU/g Conforms GB 4789.2
Yeast and mold ≤100 CFU/g Conforms GB 4789.15
Coliforms ≤10 MPN/100 g Conforms GB 4789.3
Staphylococcus aureus Negative Conforms GB 4789.10
Salmonella Negative Conforms GB 4789.4

Analytical and Source Qualification

Source comparison should use the same Icariin reference standard, assigned standard potency, sample preparation, assay calculation and chromatographic method.

  • Confirm Icariin peak identity and separation from adjacent peaks.
  • Compare main-peak purity and non-main peak distribution.
  • Evaluate replicate preparation precision.
  • Compare particle size, density and manufacturing behavior.
  • Confirm recovery in the intended process and finished-product matrix.

The finished-product method must demonstrate extraction recovery from the actual matrix before it is used to assess manufacturing loss.

Selection Summary

Select this grade when Select another format when
A defined high-purity Icariin input is required A broad Epimedium botanical profile is required
Low botanical-matrix contribution is important The accompanying botanical matrix is part of the product concept
The product uses a qualified dry-dose process Direct aqueous dispersibility is required
A dedicated delivery system can be developed A ready-to-use soluble or dispersible system is required

Technical FAQ

Which attributes should be included in a quality agreement after pilot validation?

Include only attributes shown to affect manufacturing or finished-product performance. These may include Icariin assay, specified related peaks, D10/D50/D90, density range, moisture and residual ethanol. Each added limit should be supported by blend, feeding, recovery, dissolution or stability data.

Which raw-material changes should trigger customer requalification?

Requalification should be considered after changes to botanical species, plant part, extraction or purification process, manufacturing site, solvent system, HPLC method, reference standard, particle-size process or drying process. The comparison should address the risk introduced by the specific change.

How should a laboratory premix be transferred to commercial scale?

Preserve or evaluate premix concentration, blender working volume, fill level, addition sequence, mixing intensity, discharge pattern, transfer distance and hopper residence. Commercial sampling must include discharged material and finished units.

How should colour variation be investigated when Icariin assay still complies?

Compare botanical raw-material source, related-peak distribution, moisture, particle-size distribution, drying conditions and storage exposure. Use chromatographic and physical comparison to determine whether the difference originates from related constituents, processing history or particle characteristics.

What evidence is required before approving an alternative source?

Combine aligned-method identity and assay, chromatographic-profile comparison, physical-property comparison, contaminant compliance, pilot-process recovery, finished-product uniformity and dosage-form-specific performance data.

INGREDIENT PARTNER

Request a Sample or Bulk Quote

Tell us your intended application, approximate quantity and target market. Ureda Naturals will confirm the closest grade, packaging configuration and available documentation for your project.

Ureda Naturals WeChat QR Code

Scan the QR code or
search WeChat ID: 18270717590

Ureda Naturals logo

From Natural Origin to Formulation Intent

Let’s talk ingredients

Tell us what you’re sourcing.