γ-Aminobutyric Acid (GABA)

Ureda Naturals manufactures γ-Aminobutyric Acid (GABA) with an assay of not less than 99.0%. Controlled for moisture, ash, chloride, solution transmittance, pH and microbiological quality, this grade is designed for capsules, tablets, stick packs, dry blends and qualified food and beverage formulations.

Additional information

Product Name

γ-Aminobutyric Acid (GABA)

CAS NO:

56-12-2

Assay

≥99.0%

Form

White particles or granules

MOQ

1kg

γ-Aminobutyric Acid, commonly abbreviated as GABA, is a non-protein amino acid used in nutritional supplements, functional foods and formulated beverages. Ureda Naturals manufactures GABA with an assay of not less than 99.0%, supported by controls for moisture, ash, chloride, solution transmittance, pH and microbiological quality.

This grade is primarily suited to capsules, tablets, stick packs and dry blends. Powdered beverages can normally be developed through routine formulation trials. Clear ready-to-drink beverages, gummies, protein systems and other thermally processed formulations require additional matrix-specific validation.

The standard COA establishes the chemical and microbiological quality of the incoming material. Particle size, bulk density, flow, incorporation time and process recovery should be added to the purchasing specification when they directly affect the selected manufacturing process.

Product Identity

Product name γ-Aminobutyric Acid (GABA)
Chemical name 4-Aminobutanoic acid
CAS number 56-12-2
Molecular formula C4H9NO2
Molecular weight 103.12 g/mol
Ingredient class Non-protein amino acid
Commercial form White particles or granules
Assay ≥99.0%

Standard Specification

Test Item Specification
Color White or light yellow
Physical form Crystal, crystalline powder or particles
Odor No odor
Visible foreign matter None visible
Assay ≥99.0%
Loss on drying ≤1.0%
Ash ≤0.1%
Chloride ≤0.02%
Light transmittance ≥98.0%
pH 6.5–7.5
Aerobic plate count ≤1,000 CFU/g
Coliform bacteria ≤10 CFU/g
Yeast and mold ≤50 CFU/g

Lot-specific values are reported on the Certificate of Analysis supplied with the corresponding shipment.

Application Selection

Primary-Fit Applications

The standard grade is principally suited to capsules, tablets, stick packs, sachets, dry premixes and powdered nutritional formulations. These applications still require confirmation of particle size, density and flow when dosage-unit uniformity or high-speed filling is critical.

Applications Requiring Routine Formulation Validation

Powdered beverages should be checked under the intended serving and reconstitution conditions. Relevant observations include incorporation time, reconstitution appearance, sediment after standing, final pH, taste and GABA recovery during storage.

Applications Requiring Matrix-Specific Validation

Additional development is required for clear ready-to-drink beverages, acidified beverages, gummies, chewables, protein systems, mineral-rich liquids and other thermally processed foods. In these products, acids, reducing sugars, proteins, minerals, flavors and heat treatment can alter processing behavior or finished-product performance.

Building the Purchasing Specification

The standard COA is the starting point. The final technical agreement should add the physical and functional attributes that control the customer’s manufacturing process.

Control Category Standard Raw-Material Control Add for Solid Dosage Forms Add for Liquid or Heat-Processed Products
Identity and assay Required Required Required
Loss on drying Required Required Required
Ash and chloride Required Usually sufficient Important for clear or lightly flavored systems
Transmittance Required Secondary Important for clear-beverage screening
pH Required Secondary Important during formulation development
Particle-size distribution Application control Important Relevant to incorporation rate
Bulk and tapped density Application control Important for filling and segregation Usually secondary
Flowability Application control Important for filling and compression Usually secondary
Dissolution or incorporation time Finished-product control Useful for reconstituted products Important
Turbidity and sediment Finished-product control After reconstitution where relevant Required for clear liquid systems
Thermal recovery Finished-product control Process-dependent Required when heating is used
Color development Finished-product control Process-dependent Important in heated sugar systems

These additional parameters do not replace the standard COA. They convert the general GABA grade into an application-specific purchasing specification.

How Raw-Material Properties Affect Manufacturing

Raw-Material Property Manufacturing Step Possible Process or Product Effect Recommended Verification
Particle size Premixing, conveying and filling Segregation, dusting, slow incorporation or dosage variation Sieve analysis and stratified fill testing
Bulk density Capsule filling and volumetric dosing Capsule-size limitation or variable fill weight Bulk/tapped density and machine trial
Flow behavior Hopper discharge and die filling Bridging, interrupted feeding or weight variation Flow testing and production-line observation
Moisture Storage, dispensing and blending Caking, adhesion or reduced flow Moisture and flow after controlled exposure
Assay Formula calculation Incorrect theoretical GABA contribution Calculate against the agreed minimum assay
Transmittance Liquid preparation Raw-material haze or color contribution Defined solution test followed by full-formula testing
Heat exposure Pasteurization, gummy cooking or baking Reduced recovery or color development Assay before and after the critical heat step
Packaging barrier Storage and transport Moisture uptake and physical-property change Packaging-integrity and retained-sample monitoring

The chemical specification confirms the composition of the incoming ingredient. The physical specification determines how consistently it can move through the customer’s manufacturing process.

Solid Dosage Form Development

Capsules

The quantity of GABA that fits into a capsule depends on bulk density as well as assay. A change in particle structure or packing behavior can alter the required capsule size and the consistency of volumetric filling.

Capsule trials should determine bulk and tapped density, flow through the dosing system, target fill weight, capsule size, fill-weight variation, blend uniformity and finished-capsule disintegration. When GABA is blended with low-density botanical extracts or high-density minerals, segregation should be evaluated during transfer and hopper residence.

Tablets

High chemical purity does not establish direct-compression performance. Tablet behavior depends on the physical form of GABA and the complete excipient system.

Direct compression can be evaluated when the final blend provides acceptable flow, compactability, hardness, friability, weight uniformity and disintegration. Granulation may be preferable when the direct-compression blend exhibits poor die filling, segregation, capping, lamination, insufficient hardness or excessive friability.

A change from direct compression to granulation requires renewed testing of GABA recovery, granule moisture, compression behavior, unit uniformity and disintegration.

Stick Packs and Sachets

A composite blend can meet the average GABA assay while individual sticks remain inconsistent. This is most likely when GABA and the other ingredients differ substantially in particle size or density.

  1. Characterize the particle size and density of GABA and the major ingredients.
  2. Prepare a compatible premix where necessary.
  3. Expand the premix into the full batch using a controlled addition sequence.
  4. Minimize unnecessary vibration and transfer after blending.
  5. Sample the beginning, middle and end of the filling run.
  6. Evaluate individual units rather than relying only on a composite sample.

Beverage Development

Powdered Beverages

Reconstitution should be evaluated using the intended serving quantity, water volume, water temperature and consumer mixing method. Testing in a large volume of purified laboratory water may conceal problems that appear in the commercial use condition.

The development study should record incorporation time, visible particles, sediment, final pH, taste and GABA recovery after storage.

Clear Beverages

The ≥98.0% raw-material transmittance requirement is a useful screening control, but it does not guarantee that the finished beverage will remain transparent.

A clarity investigation should distinguish three possible failure modes:

  1. Raw-material solution haze: the GABA solution is not clear under the agreed raw-material test condition.
  2. Formula-induced haze: GABA is clear in water, but turbidity appears after acids, minerals, flavors, extracts or other ingredients are added.
  3. Process- or storage-induced haze: the beverage is initially clear, but haze or sediment develops after pasteurization, cooling or storage.

The finished beverage should be evaluated for initial turbidity, post-process turbidity, visible sediment, color change, clarity at the intended storage temperature and GABA recovery through shelf life.

Complex Liquid Systems

Protein, mineral and hydrocolloid systems require separate trials because their behavior depends on pH, ionic environment and heating conditions.

A controlled comparison of the base formula with and without GABA should monitor viscosity, sedimentation, phase separation, flocculation, heat stability, final pH, sensory change and GABA recovery. Results obtained in one protein or mineral system should not be transferred directly to a materially different formulation.

Gummies and Heated Sugar Systems

Gummy, chewable and nutrition-bar processes may expose GABA to concentrated solids, acids and heat. The relevant variable is the complete time–temperature–pH profile rather than the peak temperature alone.

Because GABA contains a reactive amino group, formulations containing reducing sugars should be evaluated for non-enzymatic browning. The practical risk depends on sugar composition, temperature, hot-hold duration, pH, moisture or water activity and storage conditions.

Development batches should compare GABA addition before and after the most severe heating stage where the process permits. The selected addition point must provide complete distribution without compromising microbial control.

The finished-product study should include GABA assay before and after processing, color measurement, flavor assessment, water activity or moisture and GABA recovery during storage.

Finished-Product GABA Analysis

GABA lacks a strong native chromophore for routine UV measurement. Finished-food analysis commonly uses derivatization before chromatographic determination. Complex matrices require their own validated sample preparation because a method suitable for raw GABA cannot automatically be transferred to gummies, protein drinks, botanical blends or high-sugar products.

Distinguishing Process Loss from Analytical Loss

An apparent reduction in GABA can result from actual manufacturing loss, incomplete extraction, inconsistent derivatization, instability of the prepared derivative, interference from other amino compounds, co-elution or non-representative sampling.

The investigation should compare:

  1. the formula before the critical process;
  2. the finished product after processing;
  3. a processed matrix spiked with a known quantity of GABA.

Good recovery from the spiked processed matrix, combined with a lower result in the original processed sample, supports a process-loss investigation. Poor spike recovery indicates that extraction, derivatization or matrix interference should be addressed first.

Minimum Method-Validation Elements

  • Specificity
  • Extraction recovery
  • Linearity and working range
  • Repeatability
  • Intermediate precision
  • Accuracy through matrix spiking
  • Derivative stability
  • Sample-solution stability

Raw-Material Release and Finished-Product Validation

Controlled by the Raw-Material Specification Confirmed in the Customer’s Finished Product
Appearance and physical form Blend and dosage-unit uniformity
Odor and visible foreign matter Capsule or tablet processability
GABA assay Reconstitution behavior
Loss on drying Beverage turbidity and sediment
Ash and chloride Taste and sensory compatibility
Solution transmittance Heat-process recovery and color development
pH under the defined test condition Finished-product assay recovery
Microbiological limits Stability through the intended shelf life

Packaging, Storage and Shelf Life

  • MOQ: 1 kg
  • Bag options: 1 kg, 5 kg and 10 kg with polyethylene inner liner, aluminium barrier layer and outer carton
  • Drum options: 5 kg, 10 kg and 25 kg fibre drums with polyethylene inner liner and aluminium barrier protection
  • Storage: store in a cool, dry place in the original sealed packaging
  • Shelf life: 24 months under the stated storage conditions

After opening, minimize environmental exposure, use clean and dry dispensing equipment, reseal the remaining material promptly and protect it from humid air and contamination.

Technical FAQ

What additional specifications should be established when GABA is intended for a clear beverage?

The technical agreement should define the raw-material transmittance test conditions, particle size where it affects incorporation, dissolution time and acceptable solution appearance. The finished-product protocol should separately define initial turbidity, post-process turbidity, sediment, color and shelf-life clarity. Raw-material transmittance should not be used as the finished-beverage clarity criterion.

How should particle size and bulk density be controlled for capsules, tablets and stick packs?

The limits should be established against the intended equipment and the physical characteristics of the other ingredients. Capsule projects should prioritize density and filling consistency; tablet projects should also evaluate flow and compactability; stick packs should emphasize segregation and dosage-unit uniformity. A numerical limit should be adopted after pilot-scale performance confirms that it controls the relevant process risk.

How can GABA process loss be distinguished from poor analytical recovery?

Compare pre-process material, finished product and a GABA-spiked finished-product matrix. Poor recovery from the spiked matrix indicates an extraction, derivatization or interference problem. Acceptable spike recovery with reduced native GABA supports investigation of the manufacturing process. Sampling uniformity and derivative stability should be controlled before the results are interpreted.

What should be validated when GABA is used in a heated, high-sugar formulation?

The study should reproduce the commercial sugar composition, pH, solids level, heating profile, hot-hold time and cooling process. Evaluate GABA recovery, color, flavor and water activity immediately after production and through shelf life. Where feasible, compare early and late GABA addition to determine whether unnecessary thermal exposure can be reduced.

When is the standard ≥99% GABA specification insufficient for a commercial project?

The standard specification is insufficient whenever physical or functional behavior directly controls manufacturing performance. Examples include high-speed encapsulation, direct compression, low-dose stick packs, clear beverages and thermally processed sugar systems. These projects require additional limits or validation for particle size, density, flow, incorporation, turbidity, heat recovery or color development according to the dosage form.

INGREDIENT PARTNER

Request a Sample or Bulk Quote

Tell us your intended application, approximate quantity and target market. Ureda Naturals will confirm the closest grade, packaging configuration and available documentation for your project.

Ureda Naturals WeChat QR Code

Scan the QR code or
search WeChat ID: 18270717590

Ureda Naturals logo

From Natural Origin to Formulation Intent

Let’s talk ingredients

Tell us what you’re sourcing.